With the rapid growth of smart cities, the demand for energy efficiency in commercial plazas, residential areas, and public facilities is rising. Power equipment is widely used to improve energy efficiency, safety, and reliability.
Sources of Harmonics
Harmonic mainly comes from devices like variable frequency drives and rectifiers, used in lighting, UPS systems, and office equipment. These generate 3rd, 5th, and 7th order harmonics, with distortion rates typically reaching 10-30%.
Key Issues
High-order harmonics are found in the zero line of three-phase systems, leading to overloads, overheating, insulation damage, and even fire hazards.
Solutions
Ikonmac’s AHF filters harmonics (2nd-50th order), especially targeting the 3rd, 5th, and 7th orders. It balances three-phase systems, reduces neutral line current, and improves power factor, ensuring safer and more efficient operations.
Successful Cases
Beijing North Star TowerHarmonic Filter Project
Project Overview
Beijing Beichen Times Plaza, a high-end commercial hub, includes 12 transformers, with high harmonic loads on transformers 8, 9, and 11. Our testing confirmed significant harmonic distortion.
Analysis and Solution
The project uses energy-efficient lighting and electronic devices, generating harmonics of 3 to 11 times the fundamental frequency. This affected power quality. Our 400A Active Harmonic Filter system is now in operation to address the issue.
Module Performance
The analysis shows a significant improvement, with harmonic distortion reduced from 26.8% to 4.1%. The system’s efficiency is notably improved, ensuring the safe and stable operation of the power supply.
Before AHF
THDi 54%
After AHF
THDi 6%
Shanghai Zhao Feng Plaza
Harmonic Mitigation
Project Overview
Shanghai Zhao Feng Plaza is located in the busy Zhongshan Park area, with a total construction area of 254,516 m². The plaza includes two towers, one of 42 stories and another of 22 stories, with modern office standards and parking for 1,900 cars.
Analysis and Solution
The building’s lighting system and power devices, such as UPS and elevators, generated harmonics, affecting power quality. To address this, a 400A AHF was installed, which effectively reduced harmonic distortion.
Module Performance
The solution achieved a 34.1% reduction in harmonic distortion, with a voltage THD of 3.6%. The improved power quality has been well received by the management and professionals involved.
Before AHF
THDi 34.1%
After AHF
THDi 3.6%
More Successful Projects
Shandong Hui Jin Financial Center
Project: Harmonic Treatment
Solution: AHF
Date: May 2017
City: ShanDong
Tian Jin Mie Jiang Television Tower
Project: Harmonic Filter
Solution: AHF
Date: Jun 2018
City: TianJin
Zheng Zhou Jian Li Parksons
Proejct: Harmonic Filter
Solution: AHF
Date: Jun 2018
City: ZhengZhou